I double checked resitance measurements across each resistor and noticed one difference, the original resistor measured 470K and now reads 1/2 that after wiring (another in parallel maybe?). Anyway, here is a pic of the resistor in question. I'm getting a measurement approx 1/2 what it should be. The resistor in question is the 470K attached at the end of the sozo .022cap starting at turret 156 (the end of the middle board turret) from the end of the board containing C2 .68uF. Is this normal or has the resistor somehow been damaged?
Thanks.


Top
 Profile  
 
 Post subject:
PostPosted: Sun Jan 31, 2010 4:10 pm 
Offline
Experienced
Experienced
User avatar

Joined: Sat Jul 22, 2006 2:59 pm
Posts: 480
Location: Vancouver B.C. Canada
If it's the resistor I think it is ...you have the volume pot (normal channel)across it. The pot is a 500k so what you're measuring is dead on!!
BTW 156 is the DC voltage on that turret not is number. That'll come in handy when you first fire the amp up!
Stew


Top
 Profile  
 
 Post subject:
PostPosted: Sun Jan 31, 2010 5:22 pm 
Offline

Joined: Fri Jan 15, 2010 9:33 am
Posts: 9
Location: NorthEast Ontario/West Quebec
Thanks Stew, greatly appreciated. I suppose I can assume all numbers on top of the turrets are DC volts from the turret to ground.

Reg.


Top
 Profile  
 
 Post subject:
PostPosted: Sun Jan 31, 2010 5:35 pm 
Offline
Experienced
Experienced
User avatar

Joined: Sat Jul 22, 2006 2:59 pm
Posts: 480
Location: Vancouver B.C. Canada
Yes I think it's safe to say that all voltages on the turret board are DC referenced to ground. The ac stuff is around the power tranny and the rectifier tube. Ac voltage a generally measured across the pair like for example the filament voltage is measred across the winding or across the filament itself... not to ground.
Stew


Top
 Profile  
 
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 4 posts ] 

All times are UTC - 5 hours [ DST ]


Who is online

Users browsing this forum: Google [Bot] and 29 guests


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
Powered by phpBB® Forum Software © phpBB Group